TENMARS MALAYSIA | THERMOMETER | INFRARED THERMOMETER |HUMIDITY METER

TENMARS(ORIGINAL) AUTHORISED DISTRIBUTOR

We distribute Tenmars products in Malaysia.

Mutual prosperity and Trustworthiness.

Font Size

SCREEN

Profile

Menu Style

Cpanel
You are here: Home CO Meter TM-801 CO Meter

KKInstruments is committed to providing the best customer service before, during and after the sale.

Victoria Fatimah
Senior Engineerof Shell Malaysia Bhd
20 April 2015

KKInstruments is not only the biggest distributor for test equipments in South-East Asia, their products and service are really top-notch too!

IR MR Ali Hamzah
Senior Engineerof KL-KEPONG BHD
20 April 2015

We choose KKInstruments because:
1. Genuine product.2. Ready stock most items.3. After-sales warranty claim.4. Friendly salesperson. The team is really the best!

Mohammad Hussan
Senior Engineerof Petronas Bhd
20 April 2015

TM-801 CO Meter

3.jpg
Model No.: : TM-801
Product Description

- 4 digits backlit LCD with maximum 1,000 counts.

- Dual display of the readings for CO and Temperature.

- CO range: 0 ~ 1,000ppm.

- Temperature range: -20~50 ºC (-4~122 ºF).

- Easy to calibrate at 100ppm or 500ppm.

- USB datalogger with 8,000 records (TM-802).

Listing Details

Application

TM-801 CO meter is used for measuring the CO levels to 1000ppm.

Carbon monoxide (CO) is a poisonous gas that has no smell, color or taste. But it is very dangerous and reduces the oxygen-carrying capacity of blood that causes you unwell, illness and death.


CO LEVELS AND STANDARD:

 

Carbon monoxide content in the air

Inspiration time

Symptoms and applicable standard

0-1 ppm

 

Normal background levels.

9 ppm

 

Maximum indoor air quality level.

35 ppm

8 hours

The average exposure level per U.S. OSHA workplace standards.

50 ppm

8 hours

The maximum average exposure of the U.S. OSHA workplace standards.

0.01%(100 ppm)

2~3 hours

evacuate people from enclosed space if the CO concentration exceeds 100 ppm per OSHA exposure limit.

Mild headache.

0.04%(400 ppm)

1~2 hours

Headache occur in 2.5 hours to 3.5 hours.

0.08%(800 ppm)

45-min

Dizziness, nausea, cramps(convulsions).

0.16%(1600 ppm)

20-min

Headache, dizziness and will be dead within 2 hours.

0.32%(3200 ppm)

5~10 min

Headache, dizziness, vomiting and will be dead in 30 minutes.

0.64%(6400 ppm)

1~2 min

Headache, dizziness and will be dead within10 to 15 minutes.

1.28%(12800 ppm)

1~3 min

Cause death.

Specification

- 4 dgt LCD with maximum 1000 counts.

- Sample rate: 1 time/second

- Data output: USB PC serial interface.

- Max/Min/Average Hold.

- Data Hold.

- Low battery indication

- Auto power off with disable function.

- Adjustable alarm.

- Sample rate: 1 time/second.

CO Measurement:
 

Range

0 ~ 1000ppm

Resolution

±1ppm

Accuracy

±5% or ±2ppm

Repeatability

< 2%

Response time※

< 30 seconds.

Zero drift in long term

< 5ppm

Sensitivity drift

< 5% (per year)

Typical sensor life

3 years


Temperature Measurement
:

Range

-20~50℃/-4~122

Resolution

±0.1℃/±0.1

Accuracy

±1.0℃/±1.8

Power supply : 1.5V UM-4(AAA) battery × 6 PCS or AC100~240V or DC Adaptor 9V/0.5A(9mm).
Battery life: approx 90 hours.
Operating Temperature & Humidity: -20°C to +50°C,  
Storage Temperature & Humidity :  -10°C to +50°C, <70% RH.
.Dimension:
156×73×35mm(LxWxH).
Weight: approx 250g (Batteries not included).
Standard accessoriesUM-4(AAA)1.5V battery ×6 PCS, user’s manual,
                                            USB cable (TM-802),  AC100~240V DC9V/0.5A(9mm)×1 (TM-802),
                                            Install CD disk (TM-802)
 